Skip to main content
VDL Industrial Products

Customer case

From an Outdated System to an Efficient, Safe, and Cost-Effective Solution

Efficient Dust Extraction Solution Boosts Production for Glass Fiber Company: A VDL sister company's outdated extraction system was replaced with a JKF blower filter, resulting in improved suction, reduced noise, and efficient energy usage

Read the case
Dust extraction installation from the VDL Industrial Products case
VDL Industrial ProductsGlass fiber reinforced products ·
TypeCustomer Case
IndustryGlass fiber reinforced products
PartnerVDL Industrial Products
ProductsBF-90, JK-80MTD
Published

01 VDL Industrial Products

The customer

The client, a subsidiary of the well-known VDL Group, is a specialist in the production of glass fiber reinforced products. They operate several high-tech processing machines that are designed to produce high-quality products with consistent results. However, a significant issue arose with the milling operations on these machines as they produced large amounts of dust.

Dust extraction installation from the VDL case
Dust extraction installation from the VDL case

02 VDL Industrial Products

The case

The existing extraction system that was in place was unable to effectively remove the dust, causing it to accumulate in the work environment and creating a potential health hazard for the employees.

The customer recognized the urgent need to address this problem and approached the company for a solution. They requested the installation of a new vacuum system that would have the capacity to handle a volume of ± 20,000 m³/hour.

This would ensure that the suction capacity at the machines would be maximized and the clogging of the filter by the processed products would be prevented. The new vacuum system would provide a more effective and efficient means of removing the dust and ensuring a safer work environment for the employees.

Requested capacity
± 20,000 m³/hour
Planned future capacity
± 40,000 m³/hour
A JKF blower filter type 90-5 will be installed in the future.

03 VDL Industrial Products

The solution

The JKF Blower Filter 90-3 has been selected as the solution for the client's extraction process due to its exceptional features and capabilities. This state-of-the-art filter system has been designed to bring about a more efficient and effective extraction process, ensuring that the milling operations on the glass fiber reinforced products processing machines are carried out smoothly and without any hindrances.

The cyclonic inlet and compressed air cleaning system of the filter enhances its efficiency and ensures that the dust produced during the milling operations is extracted effectively. The placement of the filter outside the premises eliminates any potential noise pollution and creates a more pleasant work environment for the employees.

The summer/winter control system is a standout feature of the JKF Blower Filter 90-3. It allows for the captured warm air to be used for heating during the winter, which helps in reducing the energy costs, and during the summer, the warm air is expelled directly outside, providing a comfortable working environment.

The frequency control, based on pressure difference measurement, makes the system energy-efficient and cost-effective as it ensures that only the required flow rate is extracted, avoiding any wastage of energy. Each of the processing machines is connected to its own individual extraction pipe, each equipped with a gate valve that opens when the machine is in operation, providing optimal extraction flow.

The waste bin of the filter system is equipped with a full notification system, and the filter has a built-in product buffer. This means that even when the waste bin needs to be emptied, the filter continues to operate, minimizing any potential production downtime and ensuring smooth and continuous operation.

Filter installation from the VDL case
Filter installation from the VDL case

04 VDL Industrial Products

The outcome

The customer was thoroughly pleased with the solution provided, which brought about a noticeable improvement in the dust extraction process. With its advanced features, such as its cyclonic inlet and compressed air cleaning system, the JKF blower filter 90-3 was able to effectively remove dust from the machines, resulting in a cleaner work environment for employees.

The system's summer/winter control, pressure difference measurement-based frequency control, and the full notification system for the waste bin, ensured that the system was both energy-efficient and cost-effective, while also reducing downtime.

Since the customer was so satisfied with the supplied solution and production activities are going to double, expansion of the dust extraction is also necessary. For this, in consultation with the customer, we have chosen to install a new filter with the same concept, but with a doubled capacity. In the future, a JKF blower filter type 90-5 will therefore be installed with a capacity of ± 40,000 m³/hour.

The concept will be further improved by installing an internal transport system for the extracted product to an exchange container. This reduces production downtime even further and also makes changing the product discharge easier because this can be outsourced to an external company.

Read more or visit VDL Industrial Products here.

Installation detail from the VDL case
Installation detail from the VDL case

JKF components

Products referenced in this case

Related content

Explore more

Solutions

Our approach starts by understanding the process and identifying the right combination of products and expertise.

Explore solutions

Knowledge

Customer cases, videos and technical insight on industrial air and dust extraction.

Visit Knowledge

Originally published on JKF Universe on . Partner: VDL Industrial Products.

Your project

Facing a similar dust extraction challenge?

Tell us about your process, dust or airflow requirements. Our team can help assess the application and identify the right combination of products, engineering and system expertise.